Click to open the HelpDesk interface
AECE - Front page banner

Menu:


FACTS & FIGURES

JCR Impact Factor: 0.800
JCR 5-Year IF: 1.000
SCOPUS CiteScore: 2.0
Issues per year: 4
Current issue: Feb 2024
Next issue: May 2024
Avg review time: 77 days
Avg accept to publ: 48 days
APC: 300 EUR


PUBLISHER

Stefan cel Mare
University of Suceava
Faculty of Electrical Engineering and
Computer Science
13, Universitatii Street
Suceava - 720229
ROMANIA

Print ISSN: 1582-7445
Online ISSN: 1844-7600
WorldCat: 643243560
doi: 10.4316/AECE


TRAFFIC STATS

2,531,930 unique visits
1,006,662 downloads
Since November 1, 2009



Robots online now
SemanticScholar


SCOPUS CiteScore

SCOPUS CiteScore


SJR SCImago RANK

SCImago Journal & Country Rank




TEXT LINKS

Anycast DNS Hosting
MOST RECENT ISSUES

 Volume 24 (2024)
 
     »   Issue 1 / 2024
 
 
 Volume 23 (2023)
 
     »   Issue 4 / 2023
 
     »   Issue 3 / 2023
 
     »   Issue 2 / 2023
 
     »   Issue 1 / 2023
 
 
 Volume 22 (2022)
 
     »   Issue 4 / 2022
 
     »   Issue 3 / 2022
 
     »   Issue 2 / 2022
 
     »   Issue 1 / 2022
 
 
 Volume 21 (2021)
 
     »   Issue 4 / 2021
 
     »   Issue 3 / 2021
 
     »   Issue 2 / 2021
 
     »   Issue 1 / 2021
 
 
  View all issues  


FEATURED ARTICLE

Analysis of the Hybrid PSO-InC MPPT for Different Partial Shading Conditions, LEOPOLDINO, A. L. M., FREITAS, C. M., MONTEIRO, L. F. C.
Issue 2/2022

AbstractPlus






LATEST NEWS

2023-Jun-28
Clarivate Analytics published the InCites Journal Citations Report for 2022. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 0.800 (0.700 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 1.000.

2023-Jun-05
SCOPUS published the CiteScore for 2022, computed by using an improved methodology, counting the citations received in 2019-2022 and dividing the sum by the number of papers published in the same time frame. The CiteScore of Advances in Electrical and Computer Engineering for 2022 is 2.0. For "General Computer Science" we rank #134/233 and for "Electrical and Electronic Engineering" we rank #478/738.

2022-Jun-28
Clarivate Analytics published the InCites Journal Citations Report for 2021. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 0.825 (0.722 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 0.752.

2022-Jun-16
SCOPUS published the CiteScore for 2021, computed by using an improved methodology, counting the citations received in 2018-2021 and dividing the sum by the number of papers published in the same time frame. The CiteScore of Advances in Electrical and Computer Engineering for 2021 is 2.5, the same as for 2020 but better than all our previous results.

2021-Jun-30
Clarivate Analytics published the InCites Journal Citations Report for 2020. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 1.221 (1.053 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 0.961.

Read More »


    
 

  1/2015 - 17

 HIGH-IMPACT PAPER 

Performance Improvement for Quasi Periodical Disturbances in PH Control

STEBEL, K. See more information about STEBEL, K. on SCOPUS See more information about STEBEL, K. on IEEExplore See more information about STEBEL, K. on Web of Science, CHOINSKI, D. See more information about CHOINSKI, D. on SCOPUS See more information about CHOINSKI, D. on SCOPUS See more information about CHOINSKI, D. on Web of Science
 
View the paper record and citations in View the paper record and citations in Google Scholar
Click to see author's profile in See more information about the author on SCOPUS SCOPUS, See more information about the author on IEEE Xplore IEEE Xplore, See more information about the author on Web of Science Web of Science

Download PDF pdficon (973 KB) | Citation | Downloads: 791 | Views: 3,246

Author keywords
nonlinear control systems, PI control, process control, error analysis, chemical industry

References keywords
control(23), stebel(7), systems(6), process(5), model(5), choinski(5), practice(4), poland(4), measurement(4), design(4)
Blue keywords are present in both the references section and the paper title.

About this article
Date of Publication: 2015-02-28
Volume 15, Issue 1, Year 2015, On page(s): 123 - 134
ISSN: 1582-7445, e-ISSN: 1844-7600
Digital Object Identifier: 10.4316/AECE.2015.01017
Web of Science Accession Number: 000352158600017
SCOPUS ID: 84924765128

Abstract
Quick view
Full text preview
Proper operation of control systems is essential for achieving good economic results and reducing control effort. The paper is focused on presenting a new application of a well-known concept. The main scope of the paper is a practical presentation of obtaining a minimum process performance index by means of known statistical tools. This is achievable by appropriate selection of the correction value for set-point and the width of the time window of a statistical algorithm. The proposed novel algorithm was successfully implemented in the pilot neutralization process. On one hand, the proposed algorithm is a corrector of the statistical properties of the control error, and, on the other one, of a set point of the control system.


References | Cited By  «-- Click to see who has cited this paper

[1] Q. Li, Whiteley, J. Rhinehart, "An automated performance monitor for process controllers," Control Engineering Practice, vol. 12, pp. 537-553, 2004.
[CrossRef] [Web of Science Times Cited 8] [SCOPUS Times Cited 12]


[2] S. A. Zahiripour, A. A. Jalali, "A novel adaptive switching function on fault tolerable sliding mode control for uncertain stochastic systems," ISA Transactions, vol. 53, no 5, pp. 1528-1533, 2014.
[CrossRef] [Web of Science Times Cited 3] [SCOPUS Times Cited 4]


[3] R-E. Precup, S. Preitl, M-B. Radac, E. M. Petriu, C-A Dragos¸ J. K. Tar, "Experiment-Based Teaching in Advanced Control Engineering," IEEE Transactions On Education, vol. 54, no. 3, pp. 345-355, 2011.
[CrossRef] [Web of Science Times Cited 62] [SCOPUS Times Cited 69]


[4] P. Skupin, D. Choinski, "Microactuator System for Teaching Micropositioning Control System Design," International Journal of Engineering Education, vol. 30(6A), pp.1499-1508, 2014.

[5] Q. B. Jin, Q. Liu, "IMC-PID design based on model matching approach and closed-loop shaping," ISA Transactions vol. 53, pp. 462-473, 2014.
[CrossRef] [Web of Science Times Cited 40] [SCOPUS Times Cited 54]


[6] A. Besancon-Voda, "Iterative auto-calibration of digital controllers: methodology and applications," Control Engineering Practice vol. 6, pp. 345-358, 1998.
[CrossRef] [Web of Science Times Cited 19] [SCOPUS Times Cited 25]


[7] V. J. Ginter, J. K. Pieper, "Robust Gain Scheduled Control of a Hydrokinetic Turbine," IEEE Transactions On Control Systems Technology, vol. 19, no. 4, pp. 805-817, 2011.
[CrossRef] [Web of Science Times Cited 26] [SCOPUS Times Cited 38]


[8] K. Stebel, J. Czeczot, P. Laszczyk, "General tuning procedure for the nonlinear balance-based adaptive controller," International Journal of Control, vol. 87, no 1, pp. 76-89, 2014.
[CrossRef] [Web of Science Times Cited 19] [SCOPUS Times Cited 20]


[9] T. Klopot, P. Laszczyk, K. Stebel, J. Czeczot, "Flexible function block implementation of the balance-based adaptive controller as the potential alternative for PID-based industrial applications," Transactions of the Institute of Measurement and Control, vol. 36, no. 8, pp.1098-1113, 2014.
[CrossRef] [Web of Science Times Cited 26] [SCOPUS Times Cited 26]


[10] T. Hagglund, "Industrial implementation of on-line performance monitoring tools," Control Engineering Practice vol.13, pp.1383-1390 2005.
[CrossRef] [Web of Science Times Cited 47] [SCOPUS Times Cited 52]


[11] A. Kozyra, J. Wiora, A. Wiora, "Calibration of potentiometric sensor arrays with a reduced number of standard," Talanta, vol. 98, pp. 28-33, 2012.
[CrossRef] [Web of Science Times Cited 8] [SCOPUS Times Cited 8]


[12] T. Hagglund, "A control-loop performance monitor," Control Engineering Practice, vol. 3 no. 11, pp.1543-1551, 1995.
[CrossRef] [Web of Science Times Cited 177] [SCOPUS Times Cited 233]


[13] K. Patanarapeelert, T. Frank, R. Friedrich, P. Beek, I. Tang, "A data analysis method for identifying deterministic components od stable and unstable time-delayed systems with colored noise," Physics Letters A, vol. 360, pp. 190-198, 2006.
[CrossRef] [Web of Science Times Cited 9] [SCOPUS Times Cited 12]


[14] J. Bhattacharya, E. Pereda, H. Petsche, "Effective Detection of Coupling in Short and Noisy Bivariate Data," IEEE Transactions on Systems, Mam, and Cybernetics- part B: Cybernetics, vol. 33, no. 1, pp. 85-95, 2003.
[CrossRef] [Web of Science Times Cited 38] [SCOPUS Times Cited 44]


[15] Y. Wang, T. Liu, Z. Zhao, "Advanced PI control with simple learning set-point design: Application on batch processes and robust stability analysis," Chemical Engineering Science vol. 71, pp. 153-165, 2012.
[CrossRef] [Web of Science Times Cited 36] [SCOPUS Times Cited 53]


[16] K. Stebel, M. Metzger, "Distributed parameter model for pH process including distributed continuous and discrete reactant feed," Computers and Chemical Engineering vol. 38 pp. 82- 93, 2012.
[CrossRef] [Web of Science Times Cited 13] [SCOPUS Times Cited 16]


[17] T. J. McAvoy, "Time Optimal Ziegler-Nichols Control," Ind. Eng. Chem. Process Des. Develop, vol. 11, no. 1, 1972.
[CrossRef] [SCOPUS Times Cited 36]


[18] S. Mahuli, R. Rhinehart, J. Riggs. "Experimental demonstration of non-linear model-based in-line control of pH," J. Proc. Cont., vol 2, no 3, pp.145-153, 1992.
[CrossRef] [SCOPUS Times Cited 26]


[19] T. K. Gustafsson , B. O. Skrifvars , K. V. Sandstroem , K. V. Waller, "Modeling of pH for Control," Ind. Eng. Chem. Res., vol. 34, pp. 820-827, 1995.
[CrossRef] [Web of Science Times Cited 68] [SCOPUS Times Cited 92]


[20] K. Stebel, J. Czeczot, "Nostationary modelling approaches of neutralization process for model-based control," 14th IEEE International Conference on Methods and Models in Automation and Robotics MMAR 2009, Poland 2009.

[21] S. Rubio, B. Jørgensen, G. Jonsson, "pH control structure design for a periodically operated membrane separation process," Computers and Chemical Engineering, Vol. 43, pp. 120- 129, 2012.
[CrossRef] [Web of Science Times Cited 9] [SCOPUS Times Cited 10]


[22] K. Stebel, D. Choinski, "Programmable pH measurement correction in application to control," Proceedings of IFAC Workshop on Programmable Devices and Systems PDS 2004, Cracow, Poland, pp.47-52, 2004.

[23] K. Stebel, D. Choinski, "Context Model for Multi-Agent System Reconfiguration," AIMSA 2008, LNAI 5253, pp. 1-11. Springer-Verlag Berlin Heidelberg, 2008.

[24] M. Metzger, D. Choinski, "Neutralization pilot plant," Activity report 1999-2000, Institute of Automatic Control, Silesian University of Technology, Gliwice, Poland, pp.67-69, 2001.

[25] I. Leito, L. Strauss, E. Koort, V. Pihl, "Estimation of uncertainty in routine pH measurement," Springer-Verlag Accred Qual Assur, vol 7: pp.242-249, 2002.
[CrossRef] [Web of Science Times Cited 39] [SCOPUS Times Cited 42]


[26] G. Meinrath, P. Spitzer, "Uncertainties in Determination of pH," Springer-Verlag Mikrochim. Acta, vol. 135, pp.155-168 2000.
[CrossRef] [Web of Science Times Cited 45] [SCOPUS Times Cited 58]


[27] P. Brandstetter, T. Krecek, "Speed and Current Control of Permanent Magnet Synchronous Motor Drive Using IMC Controllers," Advances in Electrical and Computer Engineering vol. 12, no 4, 2012.

[28] V. G. Dovm, A. D. Borghi, "Rectification of flow measurements in continuous processes subject to fluctuations," Chemical Engineering Science vol. 56, pp. 2851-2857, 2001.
[CrossRef] [Web of Science Times Cited 4] [SCOPUS Times Cited 7]


[29] J. G. Ziegler, N. B. Nichols, "Optimum settings for automatic controllers," Transactions of the A.S.M.E. vol. 42, pp. 759-765, 1942.

[30] K. L. Chien, J. A. Hornes, J. B. Reswick, "On the automatic control of the generalized passive systems," Trans. Assoc. Soc. Mech. Eng. 1952.

[31] D. Choinski, K. Stebel, W. Nocon, "Detection of Measurement Deviation in Application to Oxygen Level Control," 12th IEEE International Conference on "Methods and Models in Automation and Robotics", Poland, vol. 1, pp. 387-392 , 2006.



References Weight

Web of Science® Citations for all references: 696 TCR
SCOPUS® Citations for all references: 937 TCR

Web of Science® Average Citations per reference: 22 ACR
SCOPUS® Average Citations per reference: 29 ACR

TCR = Total Citations for References / ACR = Average Citations per Reference

We introduced in 2010 - for the first time in scientific publishing, the term "References Weight", as a quantitative indication of the quality ... Read more

Citations for references updated on 2024-04-18 07:22 in 126 seconds.




Note1: Web of Science® is a registered trademark of Clarivate Analytics.
Note2: SCOPUS® is a registered trademark of Elsevier B.V.
Disclaimer: All queries to the respective databases were made by using the DOI record of every reference (where available). Due to technical problems beyond our control, the information is not always accurate. Please use the CrossRef link to visit the respective publisher site.

Copyright ©2001-2024
Faculty of Electrical Engineering and Computer Science
Stefan cel Mare University of Suceava, Romania


All rights reserved: Advances in Electrical and Computer Engineering is a registered trademark of the Stefan cel Mare University of Suceava. No part of this publication may be reproduced, stored in a retrieval system, photocopied, recorded or archived, without the written permission from the Editor. When authors submit their papers for publication, they agree that the copyright for their article be transferred to the Faculty of Electrical Engineering and Computer Science, Stefan cel Mare University of Suceava, Romania, if and only if the articles are accepted for publication. The copyright covers the exclusive rights to reproduce and distribute the article, including reprints and translations.

Permission for other use: The copyright owner's consent does not extend to copying for general distribution, for promotion, for creating new works, or for resale. Specific written permission must be obtained from the Editor for such copying. Direct linking to files hosted on this website is strictly prohibited.

Disclaimer: Whilst every effort is made by the publishers and editorial board to see that no inaccurate or misleading data, opinions or statements appear in this journal, they wish to make it clear that all information and opinions formulated in the articles, as well as linguistic accuracy, are the sole responsibility of the author.




Website loading speed and performance optimization powered by: 


DNS Made Easy