Click to open the HelpDesk interface
AECE - Front page banner

Menu:


FACTS & FIGURES

JCR Impact Factor: 0.800
JCR 5-Year IF: 1.000
SCOPUS CiteScore: 2.0
Issues per year: 4
Current issue: Feb 2024
Next issue: May 2024
Avg review time: 76 days
Avg accept to publ: 48 days
APC: 300 EUR


PUBLISHER

Stefan cel Mare
University of Suceava
Faculty of Electrical Engineering and
Computer Science
13, Universitatii Street
Suceava - 720229
ROMANIA

Print ISSN: 1582-7445
Online ISSN: 1844-7600
WorldCat: 643243560
doi: 10.4316/AECE


TRAFFIC STATS

2,528,162 unique visits
1,005,143 downloads
Since November 1, 2009



Robots online now
SemanticScholar


SCOPUS CiteScore

SCOPUS CiteScore


SJR SCImago RANK

SCImago Journal & Country Rank




TEXT LINKS

Anycast DNS Hosting
FEATURED ARTICLES

Analysis of the Hybrid PSO-InC MPPT for Different Partial Shading Conditions, LEOPOLDINO, A. L. M., FREITAS, C. M., MONTEIRO, L. F. C.
Issue 2/2022

AbstractPlus






LATEST NEWS

2023-Jun-28
Clarivate Analytics published the InCites Journal Citations Report for 2022. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 0.800 (0.700 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 1.000.

2023-Jun-05
SCOPUS published the CiteScore for 2022, computed by using an improved methodology, counting the citations received in 2019-2022 and dividing the sum by the number of papers published in the same time frame. The CiteScore of Advances in Electrical and Computer Engineering for 2022 is 2.0. For "General Computer Science" we rank #134/233 and for "Electrical and Electronic Engineering" we rank #478/738.

2022-Jun-28
Clarivate Analytics published the InCites Journal Citations Report for 2021. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 0.825 (0.722 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 0.752.

2022-Jun-16
SCOPUS published the CiteScore for 2021, computed by using an improved methodology, counting the citations received in 2018-2021 and dividing the sum by the number of papers published in the same time frame. The CiteScore of Advances in Electrical and Computer Engineering for 2021 is 2.5, the same as for 2020 but better than all our previous results.

2021-Jun-30
Clarivate Analytics published the InCites Journal Citations Report for 2020. The InCites JCR Impact Factor of Advances in Electrical and Computer Engineering is 1.221 (1.053 without Journal self-cites), and the InCites JCR 5-Year Impact Factor is 0.961.

Read More »


SEARCH THE JOURNAL CONTENT


Enter one or more keywords to search for.
For exact phrase matching use quotation marks (e.g. "speed controller").
Note that '*' and '?' wildcards are supported.

Search for:

Results per page:

Match: any search words all search words

Search results for: harmonic

220 results found.

22 pages of results.
Sorted by relevance / Sort by date
Year: 2013, Volume: 13, Number: 2
... D. A. Johns, "Analogue adaptive filters: past and – order harmonic rejection for digital TV tuners", in Proc. of present", ... analog frequency tracking filter in Fig. 6 is very selective, practically all the harmonics of the input signal being rejected. This result is in agreement with the ...
Terms matched: 2  -  Score: 5  -  736k
Year: 2021, Volume: 21, Number: 2
... bands and 5.8 GHz Wi-Fi band. It has been stubs are also used in harmonic suppression of microstrip shown that the method can also be used for any frequency ... dual and triple frequency stub [10] C. K. Ghosh, "Harmonics suppression of microstrip antenna using loaded rectangular microstrip antennas," IEEE Antennas and ...
Terms matched: 2  -  Score: 5  -  1,472k
Year: 2007, Volume: 7, Issue: 2
... ) "powergui" from Matlab, we notice that the total distortion of the harmonic current (THD) does not exceed 8.7%, the Figure 8. ... Erickson R., Self-Tuning Digitally and zeros without using any other conversions: Controlled Low-Harmonic Rectifier Having Fast Dynamic Response, z 1 IEEE Transactions on Power Electronics vol.18 ...
Terms matched: 2  -  Score: 5  -  565k
Year: 2019, Volume: 19, Number: 2
... of time for computational expensive evaluation various disturbances can appear at voltage electric signals functions, are processed more efficiently by the use of such as constant amplitude variations, harmonic contents, parallel computing scheme allowing their implementation to and flickers. Different sources responsible for causing obtain on-line systems. Different parallel systems disturbance events are present with ...
Terms matched: 1  -  Score: 86  -  1,585k
Year: 2011, Volume: 11, Number: 4
... , the presence of magnet segments (surface mounted, inset or buried) gives a more or less trapezoidal wave with the unavoidable Stator consequences of the high order harmonics. Therefore, slots efforts in obtaining a sinusoidal shape should be carried out. To this effect, we present in this paper an analysis based on Core ...
Terms matched: 1  -  Score: 47  -  888k
Year: 2011, Volume: 11, Number: 1
... , 3]. They modify the communications. linear BVD circuit in Fig 1.a, RM and CM having polynomial dependences on the r.m.s. value of the first harmonic in the I. INTRODUCTION resonator current. A parameter identification procedure for In the last years, the BAW AlN resonators emerged as a these models is given ...
Terms matched: 1  -  Score: 38  -  940k
Year: 2020, Volume: 20, Number: 1
... energy efficiency The extension of such practices for the connection of the indicators of the transformer and helps to reduce the high consumers by means of individual transformers mounted on harmonics of the voltage and current in the power distribution pillars seems to be useful for the Republic of Moldova network with a positive impact on power quality. It ...
Terms matched: 1  -  Score: 38  -  670k
Year: 2007, Volume: 7, Issue: 2
... and the allowable leakage current should be exceeding 72dBμV (20dBμV in plus), at the carrier specified. The electrical specification must comply with frequency and its odd harmonics, both on the L and the N national safety standards. conductors (fig. 2). Filters work on the principal of providing a large The ...
Terms matched: 1  -  Score: 23  -  349k
Year: 2022, Volume: 22, Number: 3
... be noted that the proposed method is effective log t'  a log( βI  I)  b (2) also for the relays that use harmonic component of fault By combining (1) and (2 ), the (3) will be obtained. current for detecting fault if the off-nominal frequency ...
Terms matched: 1  -  Score: 23  -  1,247k
Year: 2019, Volume: 19, Number: 1
... developments on such single-phase to three-phase motor speed controller and single-phase input current wave system for DG applications were presented in [12], wherein shaping with low total harmonic distortion (THD%) and in a two-level four-leg power converter had been proposed as phase with the AC mains. Such energy management differs an alternative to ...
Terms matched: 1  -  Score: 23  -  1,518k
Result Pages: << Previous 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Next >>


Search took 0.277 seconds


The search engine database includes all papers published after 2007, including titles, author names, abstracts, keywords, full papers text, references and citations. For papers published between 2001 and 2006, please visit the Archive section.


We invite you to try the most frequently used search terms:

system - power - control - fault - network - load - model - frequency - converter - transformer - harmonic - computer - algorithm - cancer - simulation - computer - estimate - optimal control - expert system - electromagnetic - interference - data transmission - neural network - electrocardiogram signal - model - cluster - design - wavelet - antenna - wireless sensor - coupling - robust - noise - signal processing - system identification - translation - nonlinear systems - induction motor - speed controller - shape optimization - fuzzy network - wireless sensor network


Website loading speed and performance optimization powered by: 


DNS Made Easy